Technical Specifications

Input power requirements:

At AC Transformer: 110-125 Volts AC Only

50-60 Hz

At power jack on ATX-300: 12-15 Volts AC only

Power consumption Idle: 4.2 Watts

Ringing a device: 6-11 Watts

CO Interface: REN 1.1 B

DOC (Canada) Load No. 22.6

Input ring detection: 40-150 Volts AC, 15-68 Hz

DEVICE Interface:

Battery: Nominal -48 Volt DC to devices

1, 2, and 3

Off-hook detection: 3-150 ma

Ringer frequency: 27 Hz Pseudo-sine wave

Ringing no load: Approximately 110 Volts AC

Ringing 8000 ohm impedance

(REN 1 .O): Approximately 93 VAC

Ringing 4000 ohm impedance

(REN 2.0): Approximately 74 VAC

Ringing 2667 ohm impedance

(REN 3.0): Approximately 64 VAC

Ringing short circuit: current limited to 50 ma

(impedances less than 2667 ohms not

recommended)

 

DOC Registration

 

The Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction.

 

Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an accepted method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.

 

Repairs to certified equipment should be made by an authorized maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.

 

Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.

 

The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all the devices does not exceed 100.

 

Notice:This product has been tested and meets the Class B limits for radio noise emissions set out by the Radio Interference Regulations of the Canadian Department of Communications.